• Menu
  • Skip to right header navigation
  • Skip to main content
  • Skip to primary sidebar

Edda Technology

Leading Computer Assisted Radiology & Surgery Solutions

  • Home
  • About EDDA
    • Overview
    • Management Team
    • Careers
  • Products
    • IQQA®-BodyImaging Liver
    • IQQA®-BodyImaging Lung
    • IQQA®-BodyImaging Kidney
    • IQQA®-BodyImaging Interventional
    • IQQA®–Guide
    • IQQA®–Chest
    • IQQA®–Liver
    • IQQA®-Liver Function
    • IQQA®-eQMR
  • News
  • Events
    • Upcoming Events
    • Past Events
  • Contact Us
  • Search
  • Home
  • About EDDA
    • Overview
    • Management Team
    • Careers
  • Products
    • IQQA®-BodyImaging Liver
    • IQQA®-BodyImaging Lung
    • IQQA®-BodyImaging Kidney
    • IQQA®-BodyImaging Interventional
    • IQQA®–Guide
    • IQQA®–Chest
    • IQQA®–Liver
    • IQQA®-Liver Function
    • IQQA®-eQMR
  • News
  • Events
    • Upcoming Events
    • Past Events
  • Contact Us
  • Search
EDDA Technology 3D Imaging Software

CAD boosts sensitivity of x-ray lung cancer screening AuntMinnie.com | Digital X-Ray Community

January 10, 2011 //  by Edda Technology

By James Brice

CAD boosts sensitivity of x-ray lung cancer screening

Applying computer-aided detection (CAD) to digital x-ray images can help radiologists identify significantly more small lung nodules in screening radiographs for lung cancer, according to a study of asymptomatic adults in China.

Based on 328 digital radiography (DR) and 200 computed radiography (CR) screenings read with and without CAD, Yan Xu, PhD, and colleagues at Beijing Friendship Hospital – Capital Medical University in Beijing determined that CAD dramatically improved the radiologists’ performance. Xu presented the results as a poster at the 2010 RSNA meeting.

The combined sensitivity of four radiologists for detecting small (5-15 mm diameter) pulmonary nodules rose from 65.6% when the digital images were read without CAD to 80.6% when they were re-read with CAD aiding the interpretation. A receiver operator characteristics (ROC) analysis also indicated a statistically significant improvement (p < 0.05).

CAD’s sensitivity rates for studies performed with DR and CR were 81% and 79%, respectively. The use of CAD was accompanied by an average of two false positives per case.

Cases were drawn from an archive of 128,200 lung cancer screening exams of asymptomatic adults in China. The study group was equally divided between men and women (average age, 52 years; range, 20-86). Sixty-two percent were cigarette smokers.

The four radiologists reading for the study underwent CAD training involving six supervised cases, according to Xu. CR and DR image data were stored on the hospital’s PACS. Images were viewed in a 2,000 x 2,000-pixel matrix and 12-bit grayscale format, and they were reviewed with commercially available CAD software (version 1.0, IQQA-Chest, EDDA Technology, Princeton, NJ).

Positive cases were initially identified by two chest radiologists, each having more than 15 years of diagnostic experience with pulmonary disease. They detected suspicious nodules from the selected sets of DR and CR studies and described their location, size, and probability for metastatic disease using CAD and corresponding CT scans for guidance.

During the study, the CAD algorithm generally performed poorly when assessing complicated lesions and benign abnormalities, such as pneumoconiosis and hematogenous pulmonary tuberculosis, Xu wrote in response to questions from AuntMinnie.com.

“The detected sensitivity of [CAD] will reduce in the practical application, so it should be improved,” she wrote. IQQA-Chest version 1.0 was awarded U.S. Food and Drug Administration (FDA) clearance for distribution in 2004. EDDA introduced version 2.0 of IQQA-Chest in November 2006.

Category: Uncategorized

Previous Post: « EDDA Technology Successfully Installs IQQA®-Liver at Mayo Clinic in Arizona
Next Post: Frost & Sullivan Recognizes EDDA Technology for Its Pioneering Role in Medical Imaging Analytics »

Primary Sidebar

Contact Us

609-919-9889
5 Independence Way, Princeton, NJ 08540

Request A Demo »

Explore Our Products

  • Overview
  • IQQA®-BodyImaging Liver
  • IQQA®-BodyImaging Lung
  • IQQA®-BodyImaging Kidney
  • IQQA®-BodyImaging Interventional
  • IQQA®-Guide
  • IQQA®-Chest
  • IQQA®-Liver
  • IQQA®-Liver Function
  • IQQA®-eQMR

Resources

  • Talks & Publications
  • Press & Media 2011 – Present
  • Press & Media 2004 – 2010
  • Training & Tutorials for Existing Clients
  • Download Manuals

Search this Website

EDDA-Technology-Logo
Frost & Sullivan Applauds EDDA's IQQA® Platform, an Advanced Imaging Analytics Technology that Improves Clinical Workflow and Accuracy

609-919-9889

5 Independence Way, Princeton, NJ 08540

Additional Resources

  • Talks & Publications
  • Press & Media 2011 – Present
  • Press & Media 2004 – 2010
  • Training & Tutorials for Existing Clients
  • Download Manuals

Explore Our Products

  • liver-icon

    IQQA® BodyImaging Liver

  • lung-icon

    IQQA® BodyImaging Lung

  • kidney-icon

    IQQA® BodyImaging Kidney

Copyright © 2003 – 2025 EDDA Technology, Inc. All rights are reserved. | Site Map